- مجله: Asia Oceania Journal of Nuclear Medicine and Biology
- نوع مقاله: Journal Article
- کلمات کلیدی: FDG-PET/CT,Lymphoma,SUVmax,soluble interleukin-2 receptor,Spleen
- چکیده:
- چکیده انگلیسی: Objective(s): To validate the reliability of nuclear medicine physicians in diagnosing lymphoma using positron emission tomography/computed tomography using 2-deoxy-2-[18F]fluoro-D-glucose (FDG-PET/CT) and to determine findings that reliably suggest lymphoma.
Methods: Seventy patients suspected of having lymphoma using FDG-PET/CT were enrolled in this retrospective study. Two nuclear medicine physicians read all the interpretation reports and graded the degree of suspicion by consensus (3: definitely suspicious, 2: probably suspicious, and 1: possibly suspicious). The following factors were also investigated for each patient: maximum standardized uptake value (SUVmax) of the lesions, serum level of soluble interleukin-2 receptor (sIL-2R), and the presence of splenic FDG uptake higher than that of the liver.
Results: The study group consisted of 34 lymphomas, 18 other malignancies, and 18 benign lesions according to histopathological diagnosis. No patient with a Grade 1 degree of suspicion was diagnosed as lymphoma. SUVmax and the serum level of sIL2-R could not distinguish lymphoma from other diseases. Of the 11 patients who presented with elevated splenic FDG uptake, 10 were diagnosed as having lymphoma.
Conclusion: When the degree of suspicion by nuclear medicine physicians is low, the possibility of lymphoma is also low. On the other hand, elevated splenic FDG uptake may suggest lymphoma.
- انتشار مقاله: 21-11-1395
- نویسندگان: Akira Toriihara,Masashi Nakadate,Shin Nakamura,Kazunori Kubota,Ukihide Tateishi