- چکیده:
- چکیده انگلیسی: Objective(s): We recently developed a new uptake index method for 123I-metaiodobenzylguanidine (123I-MIBG) heart uptake measurements by using planar images (radioisotope angiography and planar image) for the diagnosis of Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies
(DLB). However, the diagnostic accuracy of the uptake index was approximately equal to that of the heart-to-mediastinum ratio (H/M) for the discrimination of the LBD and non-LBD patients. A simple and pain-free uptake index method using 123I-MIBG SPECT images by modifying the uptake index method may show better diagnostic accuracy than the planar uptake index method. We hypothesized that the development of a new uptake index method for the determination of 123I-MIBG using single-photon emission computed tomography (SPECT) imaging would provide a reliable and reproducible diagnostic tool for clinical application. Regarding this, the purpose of this study was to develop a new uptake index method with a simple protocol to determine 123I-MIBG uptake on SPECT.
Methods: The 123I-MIBG input function was determined from the input counts of the pulmonary artery, assessed by analyzing the pulmonary artery time-activity curves. The 123I-MIBG output function was obtained from 123I-MIBG SPECT counts on the polar map. The uptake index was calculated through dividing the output function by the input function (SPECT uptake method). For the purpose of the study, 77 patients underwent 123I-MIBG SPECT, with an average of 31.5 min after clinical assessment and injection of the tracer. The H/M values, as well as planar and SPECT uptake indices were calculated, and then correlated with clinical features.
Results: According to the results, values obtained for LBD were significantly lower than those for non-LBD in all analyses (P<0.01). The overlap of the H/M values between the LBD and non-LBD cases ranged from 2.06 to 2.50. Furthermore, the overlap in uptake index values between LBD and non-LBD cases in planar image analysis was 1.05-1.29.
The SPECT uptake index method showed the least overlap of 1.23-1.25, with the highest value for LBD patients clearly distinguished from the lowest value for the non-LBD patients.
Conclusion: The new 123I-MIBG SPECT quantification method, developed by the input counts of the pulmonary artery, clearly distinguished LBD from non-LBD. Therefore, this method may be appropriate for routine clinical study.- انتشار مقاله: 05-09-1396
- نویسندگان: Yoshito Kamiya,Satoru Ota,Yuta Tanaka,Kosuke Yamashita,Akihiro Takaki,Shigeki Ito
- مشاهده
- جایگاه : پژوهشی
- مجله: Asia Oceania Journal of Nuclear Medicine and Biology
- نوع مقاله: Journal Article
- کلمات کلیدی: Iodine-123 metaiodobenzylguanidine,Quantification,Uptake index,Lewy body disease
- چکیده:
- چکیده انگلیسی: Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ratio is useful for distinguishing LBD from non-LBD, it fluctuates depending on the system performance of the gamma cameras. Therefore, a new, simple quantification method using 123I-MIBG uptake analysis is required for clinical study. The purpose of this study was to develop a new uptake index with a simple protocol to determine 123I-MIBG uptake on planar images.
Methods: The 123I-MIBG input function was obtained from the input counts of the pulmonary artery (PA), which were assessed by analyzing the PA time-activity curves. The heart region of interest used for determining the H/M was used for calculating the uptake index, which was obtained by dividing the heart count by the input count.
Results: Forty-eight patients underwent 123I-MIBG chest angiography and planar imaging, after clinical feature assessment and tracer injection. The H/M and 123I-MIBG uptake index were calculated and correlated with clinical features. Values for LBD were significantly lower than those for non-LBD in all analyses (P<0.001). The overlapping ranges between non-LBD and LBD were 2.15 to 2.49 in the H/M method, and 1.04 to 1.22% in the uptake index method. The diagnostic accuracy of the uptake index (area under the curve (AUC), 0.98; sensitivity, 96%; specificity, 91%; positive predictive value (PPV), 90%; negative predictive value (NPV), 93%; and accuracy, 92%) was approximately equal to that of the H/M (AUC, 0.95; sensitivity, 93%; specificity, 91%; PPV, 90%; NPV, 93%; and accuracy, 92%) for discriminating patients with LBD and non-LBD.
Conclusion: A simple uptake index method was developed using 123I-MIBG planar imaging and the input counts determined by analyzing chest radioisotope angiography images of the PA. The diagnostic accuracy of the uptake index was approximately equal to that of the H/M for discriminating patients with LBD and non-LBD.- انتشار مقاله: 07-06-1395
- نویسندگان: Yoshito Kamiya,Satoru Ota,Shintaro Okumiya,Kosuke Yamashita,Akihiro Takaki,Shigeki Ito
- مشاهده
- جایگاه : پژوهشی
- مجله: Asia Oceania Journal of Nuclear Medicine and Biology
- نوع مقاله: Journal Article
- کلمات کلیدی: SPECT,rCBF,99mTc-ECD,brain uptake,Patlak plot
- چکیده:
- چکیده انگلیسی: Objective(s): Improved brain uptake ratio (IBUR), employing 99mTc-ethyl cysteinate dimer (99mTc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H215O positron emission tomography. Clarification of differences in rCBF values obtained by Patlak plot (PP) and IBUR method is important for clinical diagnosis during the transition period between these methods. Our purpose in this study was to demonstrate the relationship between rCBF values obtained by IBUR and PP methods and to evaluate the clinical applicability of IBUR method.
Methods: The mean CBF (mCBF) and rCBF values in 15 patients were obtained using the IBUR method and compared with PP method values.
Results: Overall, mCBF and rCBF values, obtained using these independent techniques, were found to be correlated (r=0.68). The mCBF values obtained by the IBUR method ranged from 18.9 to 44.9 ml/100g/min, whereas those obtained by the PP method ranged from 34.7 to 48.1 ml/100g/min. The rCBF values obtained by the IBUR method ranged from 16.3 to 60.2 ml/100g/min, whereas those obtained by the PP method were within the range of 26.7-58.8 ml/100g/min.
Conclusion: The ranges of mCBF and rCBF values, obtained by the IBUR method, were approximately 60% lower than those obtained by the PP method; therefore, this method can be useful for diagnosing lower flow area. Re-analysis of prior PP data, using the IBUR method, could be potentially useful for the clinical follow-up of rCBF.
- انتشار مقاله: 01-06-1393
- نویسندگان: Rieko Nagaoka,Asato Ofuji,Kosuke Yamashita,Taeko Tomimatsu,Shinnichi Orita,Akihiro Takaki,Yoshikazu Uchiyama,Shigeki Ito
- مشاهده